ETurn® TLIF Cage

Intergrated with the Spine

The best of both worlds: postoperative visibility and secure fixation to bone. The BlackArmor® material is radiolucent and integrates with the vertebral endplates thanks to the rough Ti-iT® titanium coating.

The icotec ETurn® TLIF Cage may be implanted via the surgeon’s preferred posterior approach: TLIF (transforaminal lumbar interbody fusion) or PLIF (posterior lumbar interbody fusion) using bilateral cage placement.

Download Factsheet

Indications ETurn® TLIF Cage

Indications
  • Intervertebral body fusion of the lumbar spine (L2 to S1)

Please refer to the “Instructions for Use” or “Surgical Technique” manual for a more detailed description of the indications and precautions.

ETurn® Features and Benefits

  • Implants made of BlackArmor®
    for clear, postoperative visual assessment on imaging including X-ray, CT and MRI

  • Rough Ti-iT® titanium coating
    Bone tissue attaches and integrates safely into the surface of the implant due to the rough structure.1, 2

  • Functional design
    Anatomical shapes for precise and secure implantation: various sizes in width and height are available

1Hoppe et al. 2018. First Results of a New Vacuum Plasma Sprayed (VPS)Titanium-Coated Carbon/PEEK Composite Cage for Lumbar Interbody Fusion. J Funct Biomater, 9(1): 23. 

2Devine et al. 2013. Coating of carbon fiber-reinforced polyetheretherketone implants with titanium to improve bone apposition. J Biomed Mater Res B Appl Biomater, 101(4):591-8. 

This content requires HTML5 & Javascript or Adobe Flash Player Version 9 or higher.

ETurn® TLIF Cage

  • Length 32 mm / Width 12 mm

    HeightReference number
    07 mm13-57-12-32-07-ITi
    08 mm13-57-12-32-08-ITi
    09 mm13-57-12-32-09-ITi
    10 mm13-57-12-32-10-ITi
    11 mm13-57-12-32-11-ITi
    12 mm13-57-12-32-12-ITi
    13 mm13-57-12-32-13-ITi
    14 mm13-57-12-32-14-ITi
    15 mm13-57-12-32-15-ITi
  • Length 32 mm / Width 16 mm

    HeightReference number
    07 mm 13-58-16-32-07-ITi
    08 mm13-58-16-32-08-ITi
    09 mm13-58-16-32-09-ITi
    10 mm13-58-16-32-10-ITi
    11 mm13-58-16-32-11-ITi
    12 mm13-58-16-32-12-ITi
    13 mm13-58-16-32-13-ITi
    14 mm13-58-16-32-14-ITi
    15 mm13-58-16-32-15-ITi

Contact Us!

Quickform

Quickform

Additional BlackArmor® Implants

PLIF Cage

Anterior wedge serves to guide and anchor the implant...

Cervical Cage

Simplified insertion with an anatomical shape and Ti-iT® titanium coating for secure fixation to bone...