{"id":4273,"date":"2021-12-19T18:56:07","date_gmt":"2021-12-19T17:56:14","guid":{"rendered":"https:\/\/www.icotec-medical.com\/radiation-therapy\/"},"modified":"2023-03-28T12:16:44","modified_gmt":"2023-03-28T10:16:44","slug":"radiation-therapy","status":"publish","type":"page","link":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/","title":{"rendered":"Radiation Therapy"},"content":{"rendered":"\n<div class=\"wp-block-getwid-section\"><div class=\"wp-block-getwid-section__wrapper\"><div class=\"wp-block-getwid-section__inner-wrapper\"><div class=\"wp-block-getwid-section__background-holder\"><div class=\"wp-block-getwid-section__background\"><\/div><div class=\"wp-block-getwid-section__foreground\"><\/div><\/div><div class=\"wp-block-getwid-section__content\"><div class=\"wp-block-getwid-section__inner-content\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<h2 class=\"wp-block-heading\"><strong><strong><strong>Radiate as if It Were a Native Spine<\/strong><\/strong><\/strong><\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"has-extra-small-font-size\">Treatment paths vary depending on tumor type. Tumor resection and spinal stabilization using implants are often combined with subsequent radiation therapy. Implant material is crucial for the most successful adjuvant radiation therapy. Implants made of titanium have been shown to reduce local tumor control.<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"1\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\"  role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">1<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"1\">Snider et al. (2018): Long-Term Outcomes and Prognostic Factors After Pencil-Beam Scanning Proton Radiation Therapy for Spinal Chordomas: A Large, Single-Institution Cohort. International Journal of Radiation Oncology \u2013 Biology \u2013 Physics. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29619966\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 29619966<\/a>)<\/span><\/span>With implants made of artifact-free and radiolucent <a href=\"https:\/\/www.icotec-medical.com\/en-us\/blackarmor\/\">BlackArmor<sup>\u00ae<\/sup> Carbon\/PEEK<\/a>, you can perform radiation therapy without restrictions, just as you would with a native, uninstrumented spine<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"2\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\"  role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">2<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"2\">Shi et al. (2022): Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning. Technology in Cancer Research &amp; Treatment. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35410544\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 35410544<\/a>)<\/span><\/span>\u2013  the best conditions for targeted radiation therapy for spinal neoplasms.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-vertically-aligned-center has-dark-color has-lightgray-background-color has-text-color has-background\" style=\"grid-template-columns:17% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"401\" height=\"401\" src=\"https:&#47;&#x2f;w&#x77;&#x77;&#46;&#x69;c&#111;&#x74;&#101;&#x63;-&#109;&#x65;d&#x69;c&#97;&#x6c;&#46;&#x63;&#x6f;&#109;&#x2f;w&#112;&#x2d;&#99;&#x6f;n&#116;&#x65;&#110;&#x74;\/&#117;&#x70;l&#x6f;&#x61;&#100;&#x73;\/&#50;&#x30;&#50;&#x32;\/&#49;&#x32;&#47;&#x30;8&#95;&#x45;r&#x77;e&#105;&#x74;e&#x72;&#x74;&#101;&#x54;h&#101;&#x72;&#97;&#x70;i&#101;&#x5f;&#119;&#x2d;b&#103;&#x40;4&#x78;&#x2e;&#112;&#x6e;g\" alt=\"\" class=\"wp-image-1872 size-full\" srcset=\"https:&#47;\/&#119;w&#119;&#46;&#x69;c&#x6f;t&#x65;c&#x2d;m&#x65;d&#x69;c&#x61;l&#x2e;c&#x6f;m&#x2f;&#119;&#x70;&#45;&#x63;&#111;&#x6e;&#116;&#x65;&#110;&#x74;&#47;&#x75;&#112;&#x6c;&#111;&#x61;&#100;&#x73;&#47;&#x32;&#48;&#x32;&#50;&#x2f;&#49;2&#47;0&#56;_&#x45;r&#x77;e&#x69;t&#x65;r&#x74;e&#x54;h&#x65;r&#x61;p&#x69;e&#x5f;&#119;&#x2d;&#98;&#x67;&#64;&#x34;&#120;&#x2e;&#112;&#x6e;&#103; 401w, https:\/\/www&#46;icotec&#45;&#109;&#101;&#100;&#105;&#99;&#97;&#108;&#46;&#99;&#111;&#109;&#47;&#119;&#112;&#x2d;&#x63;&#x6f;&#x6e;&#x74;&#x65;&#x6e;&#x74;&#x2f;&#x75;&#x70;&#x6c;&#x6f;&#x61;&#x64;&#x73;&#x2f;&#x32;&#x30;&#x32;&#x32;&#x2f;&#x31;2\/08_Erweite&#114;&#116;&#101;&#84;&#104;&#101;&#114;&#97;&#112;&#105;&#101;&#95;&#119;&#45;&#98;&#x67;&#x40;&#x34;&#x78;&#x2d;&#x33;&#x30;&#x30;&#x78;&#x33;&#x30;&#x30;&#x2e;&#x70;&#x6e;&#x67; 300w, https:&#x2f;&#x2f;&#x77;&#119;&#119;&#46;i&#x63;&#x6f;&#x74;&#101;&#99;-m&#x65;&#x64;&#x69;&#99;&#97;l&#46;&#x63;&#x6f;&#x6d;&#47;&#119;p-&#x63;&#x6f;&#x6e;&#116;&#101;nt&#x2f;&#x75;&#x70;&#108;&#111;&#97;d&#x73;&#x2f;&#x32;&#x30;&#50;&#50;\/&#x31;&#x32;&#x2f;&#x30;&#56;&#95;Er&#x77;&#x65;&#x69;&#116;&#101;rt&#x65;&#x54;&#x68;&#101;&#114;ap&#x69;&#x65;&#x5f;&#119;&#45;bg&#x40;&#x34;&#x78;&#45;&#49;50&#x78;&#x31;&#x35;&#48;&#46;&#112;n&#x67; 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 class=\"has-large-font-size wp-block-heading\" id=\"strahlentherapie\"><strong><strong>Expanded Therapy Options<\/strong><\/strong><\/h3>\n\n\n\n<p class=\"has-darkgray-color has-text-color has-extra-small-font-size\">A significant benefit of BlackArmor<sup>\u00ae<\/sup> Carbon\/PEEK compared to titanium implants is the expanded treatment spectrum. The material characteristics allow unrestricted access to stereotactic irradiation<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"2\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"2\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">2<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"2\">Shi et al. (2022): Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning. Technology in Cancer Research &amp; Treatment. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35410544\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 35410544<\/a>)<\/span><\/span><span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"3\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\"  role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">3<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"3\">Henzen et al. (2022): Feasibility of Postoperative Spine Stereotactic Body Radiation Therapy in Proximity of Carbon and Titanium Hybrid Implants Using a Robotic Radiotherapy Device. Radiation Oncology. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35549961\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 35549961<\/a>)<\/span><\/span>and proton therapy.<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"4\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"4\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">4<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"4\">Poel et al. (2020): Assessing the Advantages of CFR-PEEK over Titanium Spinal Stabilization Implants in Proton Therapy \u2013 A Phantom Study. Physics in Medicine and Biology. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32315991\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32315991<\/a>)<\/span><\/span><span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"5\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"5\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">5<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"5\">M\u00fcller et al. (2020): The Dosimetric Impact of Stabilizing Spinal Implants in Radiotherapy Treatment Planning with Protons and Photons: Standard Titanium Alloy vs. Radiolucent Carbon-Fiber-Reinforced PEEK Systems. Journal of Applied Clinical Medical Physics. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32476247\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32476247<\/a>)<\/span><\/span><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-vertically-aligned-center has-dark-color has-lightgray-background-color has-text-color has-background\" style=\"grid-template-columns:17% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"401\" height=\"401\" src=\"https:&#47;&#x2f;&#x77;&#119;&#x77;&#x2e;i&#x63;&#x6f;t&#101;&#x63;-&#109;&#x65;d&#105;&#x63;a&#108;&#x2e;c&#111;&#x6d;&#x2f;&#119;&#x70;&#x2d;&#99;&#x6f;&#x6e;t&#x65;&#x6e;t&#47;&#x75;p&#108;&#x6f;a&#100;&#x73;\/&#50;&#x30;2&#50;&#x2f;&#x31;&#50;&#x2f;&#x30;&#49;&#x5f;&#x5a;i&#x65;&#x6c;v&#111;&#x6c;u&#109;&#x65;n&#95;&#x77;-&#98;&#x67;&#64;&#52;&#x78;&#x2e;&#112;&#x6e;&#x67;\" alt=\"\" class=\"wp-image-1868 size-full\" srcset=\"https:\/\/&#119;&#119;&#119;&#x2e;&#x69;&#x63;&#x6f;te&#99;&#45;&#109;&#x65;&#x64;&#x69;&#x63;al&#46;&#99;&#111;&#x6d;&#x2f;&#x77;&#x70;-c&#111;&#110;&#116;&#x65;&#x6e;&#x74;&#x2f;up&#108;&#111;&#97;&#x64;&#x73;&#x2f;&#x32;02&#50;&#47;&#49;&#x32;&#x2f;&#x30;&#x31;_Z&#105;&#101;&#108;&#x76;&#x6f;&#x6c;&#x75;me&#110;&#95;&#119;&#x2d;&#x62;&#x67;&#x40;4x&#46;&#112;&#110;&#x67; 401w, https:\/\/&#119;&#119;&#119;&#x2e;&#x69;&#x63;&#x6f;te&#99;&#45;&#109;&#x65;&#x64;&#x69;&#x63;al&#46;&#99;&#111;&#x6d;&#x2f;&#x77;&#x70;-c&#111;&#110;&#116;&#x65;&#x6e;&#x74;&#x2f;up&#108;&#111;&#97;&#x64;&#x73;&#x2f;&#x32;02&#50;&#47;&#49;&#x32;&#x2f;&#x30;&#x31;_Z&#105;&#101;&#108;&#x76;&#x6f;&#x6c;&#x75;me&#110;&#95;&#119;&#x2d;&#x62;&#x67;&#x40;4x&#45;&#51;&#48;&#x30;&#x78;&#x33;&#x30;0&#46;p&#110;&#103; 300w, https:&#x2f;&#47;&#119;w&#x77;&#x2e;&#105;c&#x6f;&#x74;&#101;c&#x2d;&#x6d;&#101;d&#x69;&#x63;&#97;l&#x2e;&#x63;&#111;m&#x2f;&#x77;&#112;&#45;c&#x6f;&#x6e;&#116;e&#x6e;&#x74;&#47;u&#x70;&#x6c;&#111;a&#x64;&#x73;&#47;2&#x30;&#x32;&#50;\/&#x31;&#x32;&#47;&#48;1&#x5f;&#x5a;&#105;e&#x6c;&#x76;&#111;l&#x75;&#x6d;&#101;n&#x5f;&#x77;&#45;b&#x67;&#x40;&#52;x&#x2d;&#x31;&#53;&#48;x&#x31;&#x35;&#48;&#46;&#x70;&#x6e;&#103; 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 class=\"has-large-font-size wp-block-heading\" id=\"strahlentherapie\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"><strong>Robust Plan Quality<\/strong><\/mark><\/h3>\n\n\n\n<p class=\"has-darkgray-color has-text-color has-extra-small-font-size\">BlackArmor<sup>\u00ae<\/sup> Carbon\/PEEK implants make both exact and quick radiation therapy planning possible. The material can be safely used in both proton and photon irradiation.<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"2\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"2\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">2<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"2\">Shi et al. (2022): Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning. Technology in Cancer Research &amp; Treatment. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35410544\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 35410544<\/a>)<\/span><\/span> <span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"4\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"4\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">4<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"4\">Poel et al. (2020): Assessing the Advantages of CFR-PEEK over Titanium Spinal Stabilization Implants in Proton Therapy \u2013 A Phantom Study. Physics in Medicine and Biology. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32315991\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32315991<\/a>)<\/span><\/span><span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"5\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"5\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">5<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"5\">M\u00fcller et al. (2020): The Dosimetric Impact of Stabilizing Spinal Implants in Radiotherapy Treatment Planning with Protons and Photons: Standard Titanium Alloy vs. Radiolucent Carbon-Fiber-Reinforced PEEK Systems. Journal of Applied Clinical Medical Physics. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32476247\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32476247<\/a>)<\/span><\/span><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-vertically-aligned-center has-dark-color has-lightgray-background-color has-text-color has-background\" style=\"grid-template-columns:17% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"401\" height=\"401\" src=\"https:&#x2f;&#47;w&#x77;&#x77;&#46;i&#x63;&#x6f;&#116;e&#x63;&#45;m&#x65;&#x64;&#105;c&#x61;&#x6c;&#46;c&#x6f;&#109;&#47;&#x77;&#x70;&#45;c&#x6f;&#x6e;&#116;e&#x6e;&#116;&#47;u&#x70;&#108;o&#x61;&#x64;&#115;\/&#x32;&#x30;&#50;2&#x2f;&#49;2&#x2f;&#x30;&#50;-&#x30;&#x36;&#95;D&#x6f;&#115;&#105;&#x73;&#x62;&#101;r&#x65;&#x63;&#104;n&#x75;&#x6e;&#103;_&#x77;&#45;b&#x67;&#x40;&#52;x&#x2e;&#x70;&#110;g\" alt=\"\" class=\"wp-image-1870 size-full\" srcset=\"https:&#47;\/&#x77;w&#x77;&#46;&#x69;&#99;&#x6f;&#116;&#x65;&#99;-&#x6d;e&#x64;i&#x63;&#97;&#x6c;&#46;&#x63;&#111;&#x6d;&#47;w&#x70;-&#x63;o&#x6e;&#116;&#x65;&#110;&#x74;&#47;&#x75;&#112;l&#x6f;a&#x64;s&#x2f;&#50;&#x30;&#50;&#x32;&#47;&#x31;&#50;\/&#x30;2&#x2d;0&#x36;&#95;&#x44;&#111;&#x73;&#105;s&#x62;e&#x72;e&#x63;&#104;&#x6e;&#117;&#x6e;&#103;&#x5f;&#119;-&#x62;g&#x40;4&#x78;&#46;&#x70;&#110;&#x67; 401w, https:&#x2f;&#x2f;&#119;w&#x77;&#x2e;&#105;&#99;o&#x74;&#x65;&#99;&#45;m&#x65;&#x64;&#105;ca&#x6c;&#x2e;&#99;o&#x6d;&#x2f;&#119;&#112;-&#x63;&#x6f;&#110;&#116;e&#x6e;&#x74;&#47;up&#x6c;&#x6f;&#97;d&#x73;&#x2f;&#50;&#48;2&#x32;&#x2f;&#49;&#50;\/&#x30;&#x32;&#45;06&#x5f;&#x44;&#111;s&#x69;&#x73;&#x62;&#101;r&#x65;&#x63;&#104;&#110;u&#x6e;&#x67;&#95;&#119;-&#x62;&#x67;&#64;4&#x78;&#x2d;&#x33;&#48;0&#x78;&#x33;&#48;&#48;&#46;&#x70;&#x6e;&#103; 300w, https:&#47;&#x2f;w&#x77;&#x77;&#46;&#x69;c&#x6f;&#x74;&#101;&#x63;-&#x6d;&#x65;&#100;&#x69;c&#x61;&#x6c;&#46;&#x63;o&#x6d;&#x2f;&#119;&#x70;-&#x63;&#x6f;&#110;&#x74;e&#x6e;&#x74;&#47;&#x75;p&#x6c;&#x6f;&#97;&#x64;s&#x2f;&#x32;&#48;&#x32;2&#x2f;&#x31;&#50;&#x2f;0&#x32;&#x2d;&#48;&#x36;_&#x44;&#x6f;&#115;&#x69;s&#x62;&#x65;&#114;&#x65;c&#x68;&#x6e;&#117;&#x6e;g&#x5f;&#x77;&#45;&#x62;g&#x40;&#x34;&#120;&#x2d;1&#x35;&#x30;&#120;&#x31;5&#x30;&#x2e;&#112;&#x6e;g 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 class=\"has-large-font-size wp-block-heading\" id=\"strahlentherapie\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"><strong>Precise Radiation Application<\/strong><\/mark><\/h3>\n\n\n\n<p class=\"has-extra-small-font-size\">The radiolucent BlackArmor<sup>\u00ae<\/sup> Carbon\/PEEK allows precise and homogeneous application of the prescribed radiation dose in the target volume. This significantly reduces the risk of underdosing the tumor tissue.<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"4\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"4\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">4<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"4\">Poel et al. (2020): Assessing the Advantages of CFR-PEEK over Titanium Spinal Stabilization Implants in Proton Therapy \u2013 A Phantom Study. Physics in Medicine and Biology. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32315991\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32315991<\/a>)<\/span><\/span><span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"5\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"5\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">5<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"5\">M\u00fcller et al. (2020): The Dosimetric Impact of Stabilizing Spinal Implants in Radiotherapy Treatment Planning with Protons and Photons: Standard Titanium Alloy vs. Radiolucent Carbon-Fiber-Reinforced PEEK Systems. Journal of Applied Clinical Medical Physics. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32476247\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32476247<\/a>)<\/span><\/span><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-vertically-aligned-center has-dark-color has-lightgray-background-color has-text-color has-background\" style=\"grid-template-columns:17% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"401\" height=\"401\" src=\"https:\/\/w&#119;&#119;&#46;&#105;&#x63;&#x6f;&#x74;&#x65;&#x63;&#x2d;&#x6d;edi&#99;&#97;&#108;&#46;&#99;&#x6f;&#x6d;&#x2f;&#x77;&#x70;&#x2d;cont&#101;&#110;&#116;&#47;&#x75;&#x70;&#x6c;&#x6f;&#x61;&#x64;s\/20&#50;&#50;&#47;&#49;&#x32;&#x2f;&#x30;&#x37;&#x5f;&#x52;&#x69;sik&#111;&#111;&#114;&#103;&#97;&#x6e;&#x65;&#x5f;&#x77;&#x2d;&#x62;g&#64;4&#120;&#46;&#112;&#110;&#103;\" alt=\"\" class=\"wp-image-1871 size-full\" srcset=\"https:&#x2f;&#x2f;&#119;w&#x77;&#x2e;&#105;co&#x74;&#x65;&#99;-&#x6d;&#x65;&#100;&#105;c&#x61;&#x6c;&#46;c&#x6f;&#x6d;&#47;&#119;p&#x2d;&#x63;&#111;n&#x74;&#x65;&#110;&#116;\/&#x75;&#x70;&#108;o&#x61;&#x64;&#115;&#47;2&#x30;&#x32;&#50;\/&#x31;&#x32;&#x2f;&#48;7&#x5f;&#x52;&#105;si&#x6b;&#x6f;&#111;r&#x67;&#x61;&#110;&#101;_&#x77;&#x2d;&#98;g&#x40;&#x34;&#120;&#46;p&#x6e;&#x67; 401w, https:&#x2f;&#47;w&#x77;&#119;&#46;&#x69;&#99;o&#x74;&#x65;&#99;&#x2d;&#x6d;&#101;d&#x69;&#99;a&#x6c;&#46;c&#x6f;&#x6d;&#47;&#x77;&#x70;&#45;c&#x6f;&#110;t&#x65;&#110;t&#x2f;&#117;p&#x6c;&#x6f;&#97;&#x64;&#x73;&#47;2&#x30;&#50;2&#x2f;&#49;2&#x2f;&#x30;&#55;&#x5f;&#x52;&#105;s&#x69;&#107;o&#x6f;&#114;g&#x61;&#110;e&#x5f;&#x77;&#45;&#x62;&#x67;&#64;4&#x78;&#45;3&#x30;&#48;x&#x33;&#x30;&#48;&#x2e;&#x70;&#110;g 300w, https:\/&#47;&#x77;&#x77;w&#46;&#105;&#x63;&#x6f;t&#101;&#99;&#x2d;&#x6d;e&#100;&#x69;&#x63;&#x61;l&#46;&#x63;&#x6f;m&#47;&#119;&#x70;&#x2d;c&#111;&#110;&#x74;&#x65;n&#116;&#x2f;&#x75;&#x70;l&#111;&#x61;&#x64;s\/&#50;&#x30;&#x32;2&#47;&#49;&#x32;&#x2f;0&#55;&#95;&#x52;&#x69;s&#105;&#x6b;&#x6f;or&#103;&#x61;&#x6e;e&#95;&#119;&#x2d;&#x62;g&#64;&#52;&#x78;&#x2d;1&#53;&#x30;&#x78;15&#48;&#x2e;&#x70;n&#103; 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 class=\"has-large-font-size wp-block-heading\" id=\"strahlentherapie\"><strong>Protection of the Healthy Tissue<\/strong><\/h3>\n\n\n\n<p class=\"has-darkgray-color has-text-color has-extra-small-font-size\">The radiolucency of our material ensures high-precision radiation. The spinal cord and organs at risk can be precisely omitted.<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"2\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"2\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">2<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"2\">Shi et al. (2022): Comprehensive Evaluation of Carbon-Fiber-Reinforced Polyetheretherketone (CFR-PEEK) Spinal Hardware for Proton and Photon Planning. Technology in Cancer Research &amp; Treatment. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35410544\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 35410544<\/a>)<\/span><\/span><span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"5\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\" refnum=\"5\" role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">5<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"5\">M\u00fcller et al. (2020): The Dosimetric Impact of Stabilizing Spinal Implants in Radiotherapy Treatment Planning with Protons and Photons: Standard Titanium Alloy vs. Radiolucent Carbon-Fiber-Reinforced PEEK Systems. Journal of Applied Clinical Medical Physics. (<a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32476247\/\" target=\"_blank\" rel=\"noreferrer noopener\">PubMed, PMID: 32476247<\/a>)<\/span><\/span><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile is-vertically-aligned-center has-dark-color has-lightgray-background-color has-text-color has-background\" style=\"grid-template-columns:17% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"401\" height=\"401\" src=\"https:&#47;&#x2f;&#x77;&#119;&#x77;&#x2e;&#105;&#x63;&#x6f;&#116;&#x65;&#x63;&#45;&#x6d;&#x65;&#100;&#x69;&#x63;&#97;&#x6c;&#x2e;&#99;&#x6f;&#x6d;&#47;&#x77;&#x70;-&#x63;&#x6f;n&#x74;&#x65;n&#116;&#x2f;u&#112;&#x6c;o&#97;&#x64;s&#47;&#x32;0&#50;&#x32;\/&#49;&#x32;\/&#48;&#x39;_&#77;&#x52;T&#95;&#x77;-&#98;&#x67;&#64;&#52;&#x78;&#46;&#112;&#x6e;g\" alt=\"\" class=\"wp-image-1869 size-full\" srcset=\"https:&#x2f;&#x2f;&#x77;&#x77;&#x77;&#x2e;&#x69;&#x63;&#x6f;&#x74;&#x65;&#x63;&#x2d;&#x6d;&#101;&#100;&#105;&#99;&#97;&#108;&#46;&#99;&#111;&#109;&#47;wp-conte&#x6e;&#x74;&#x2f;&#x75;&#x70;&#x6c;&#x6f;&#x61;&#x64;&#x73;&#x2f;&#x32;&#x30;&#x32;&#x32;&#47;&#49;&#50;&#47;&#48;&#57;&#95;&#77;&#82;&#84;_w-bg&#64;4x&#x2e;&#x70;&#x6e;&#x67; 401w, https:\/&#47;&#x77;&#x77;&#x77;&#46;&#105;&#x63;&#x6f;&#x74;e&#99;&#x2d;&#x6d;&#x65;d&#105;&#x63;&#x61;&#x6c;&#46;&#99;&#x6f;&#x6d;&#x2f;w&#112;&#x2d;&#x63;&#x6f;n&#116;&#x65;&#x6e;&#x74;\/&#117;&#x70;&#x6c;&#x6f;a&#100;&#x73;&#x2f;&#x32;0&#50;&#x32;&#x2f;&#x31;2&#47;&#x30;&#x39;&#x5f;M&#82;&#x54;&#x5f;&#x77;-&#98;&#x67;&#x40;&#x34;x&#45;&#x33;&#x30;&#x30;x&#51;&#x30;&#x30;&#x2e;p&#110;&#x67; 300w, https:&#x2f;&#x2f;&#x77;&#x77;&#119;&#46;ico&#x74;&#x65;&#x63;&#x2d;&#109;&#101;dic&#x61;&#x6c;&#x2e;&#x63;&#111;&#109;&#47;wp&#x2d;&#x63;&#x6f;&#x6e;&#116;&#101;&#110;t\/&#x75;&#x70;&#x6c;&#x6f;&#97;&#100;&#115;\/2&#x30;&#x32;&#x32;&#x2f;&#49;&#50;&#47;09&#x5f;&#x4d;&#x52;&#x54;&#95;&#119;&#45;bg&#x40;&#x34;&#x78;&#x2d;&#49;&#53;&#48;x1&#x35;&#x30;&#x2e;&#x70;&#110;&#103; 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h3 class=\"has-large-font-size wp-block-heading\" id=\"strahlentherapie\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"><strong>Reduced Exposure Diagnostic to Radiation<\/strong><\/mark><\/h3>\n\n\n\n<p class=\"has-extra-small-font-size\">BlackArmor<sup>\u00ae<\/sup> Carbon\/PEEK enables high-quality MR imaging for planning radiation therapy. CT myelography to delineate the spinal cord from the epidural tumor volume, which is stressful for the patient, can potentially be avoided.<span class=\"modern-footnote\"><sup class=\"modern-footnotes-footnote modern-footnotes-footnote--expands-on-desktop \" data-mfn=\"6\" data-mfn-post-scope=\"0000000048646313000000000e8408b5_4273\"><a href=\"javascript:void(0)\"  role=\"button\" aria-pressed=\"false\" aria-describedby=\"mfn-content-0000000048646313000000000e8408b5_4273\">6<\/a><\/sup><span id=\"mfn-content-0000000048646313000000000e8408b5_4273\" role=\"tooltip\" class=\"modern-footnotes-footnote__note\" tabindex=\"0\" data-mfn=\"6\">Almeida et al. (2022): Carbon Fiber Reinforced PEEK Implants for Spine Tumors: A Single Center Experience. The Spine Journal, Volume 22, Issue 9, Supplement, Page S185 (<a href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/S1529943022006611\" target=\"_blank\" rel=\"noreferrer noopener\">Link<\/a>)<\/span><\/span><\/p>\n<\/div><\/div>\n\n\n<div id=\"quotes\" class=\"\">\n\n      <div class=\"quote center\">\n      <div class=\"container\">\n        \n        <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/32476247\/\" target=\"_blank\">        \n                \n        <div class=\"text\">\n          \n          <blockquote>\n            \u201cThis gain in dosimetric quality will consequently reduce the risk of tumor underdosage and overdosage of critical OARs.\u201d          <\/blockquote>\n          <div class=\"author\">\n            <div class=\"name\">M\u00fcller et al., 2020<\/div>\n            <div class=\"position\"><\/div>\n          <\/div>\n          \n        <\/div>\n        \n        <\/a>      \n      <\/div>\n    <\/div>\n        <div class=\"quote center\">\n      <div class=\"container\">\n        \n        <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35410544\/\" target=\"_blank\">        \n                \n        <div class=\"text\">\n          \n          <blockquote>\n            \u201cThe CFR-PEEK implant has similar clinical properties to a normal spine for proton planning, allowing us to pass protons through the material and achieve superior target coverage and OAR sparing under nominal and uncertainty conditions.\u201d          <\/blockquote>\n          <div class=\"author\">\n            <div class=\"name\">Shi et al., 2022<\/div>\n            <div class=\"position\"><\/div>\n          <\/div>\n          \n        <\/div>\n        \n        <\/a>      \n      <\/div>\n    <\/div>\n    \n<\/div>\n\n<script>\n\n  jQuery(document).ready( function($){\n  \n    $(\"#quotes\").slick({\n      slidesToShow: 1,\n      slidesToScroll: 1,\n      fade: true,\n      loop: true,\n      infinite: false,\n      arrows: true,\n      adaptiveHeight: true,\n      dots: true,\n      autoplay: false,\n      autoplaySpeed: 4000,\n    });\n    \n  });\n\n<\/script>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\"><strong><strong>The next step in tumor control: <\/strong><\/strong><br>Aftercare<\/h2>\n\n\n\n<p class=\"has-darkgray-color has-text-color has-extra-small-font-size\">BlackArmor<sup>\u00ae<\/sup> Carbon\/PEEK enables an improvement of the entire treatment pathway \u2013 also in aftercare.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-23b93fc6 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-red-background-color has-background wp-element-button\" href=\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/aftercare\/\">Learn more<\/a><\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h5 class=\"wp-block-heading has-text-align-center has-red-color has-text-color\"><strong>Do you have any further questions?<\/strong><\/h5>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-center\">We are here for you.<\/h1>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-red-background-color has-background wp-element-button\" href=\"https:\/\/www.icotec-medical.com\/en-us\/contact\/\">Contact us<\/a><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":4330,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-4273","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Optimal Radiation Therapy for Spinal Tumor Patients I icotec<\/title>\n<meta name=\"description\" content=\"The right implant material is crucial for the success of adjuvant radiation therapy. This makes icotec implants the ideal choice for the treatment of spinal tumors and metastases.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Optimal Radiation Therapy for Spinal Tumor Patients I icotec\" \/>\n<meta property=\"og:description\" content=\"The right implant material is crucial for the success of adjuvant radiation therapy. This makes icotec implants the ideal choice for the treatment of spinal tumors and metastases.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/\" \/>\n<meta property=\"og:site_name\" content=\"icotec\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-28T10:16:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/\",\"url\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/\",\"name\":\"Optimal Radiation Therapy for Spinal Tumor Patients I icotec\",\"isPartOf\":{\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png\",\"datePublished\":\"2021-12-19T17:56:14+00:00\",\"dateModified\":\"2023-03-28T10:16:44+00:00\",\"description\":\"The right implant material is crucial for the success of adjuvant radiation therapy. This makes icotec implants the ideal choice for the treatment of spinal tumors and metastases.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#primaryimage\",\"url\":\"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png\",\"contentUrl\":\"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.icotec-medical.com\/en-us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tumor Therapy\",\"item\":\"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Radiation Therapy\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.icotec-medical.com\/en-us\/#website\",\"url\":\"https:\/\/www.icotec-medical.com\/en-us\/\",\"name\":\"icotec\",\"description\":\"Innovative Implantate aus kohlefaserverst\u00e4rktem Kunststoff\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.icotec-medical.com\/en-us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Optimal Radiation Therapy for Spinal Tumor Patients I icotec","description":"The right implant material is crucial for the success of adjuvant radiation therapy. This makes icotec implants the ideal choice for the treatment of spinal tumors and metastases.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/","og_locale":"en_US","og_type":"article","og_title":"Optimal Radiation Therapy for Spinal Tumor Patients I icotec","og_description":"The right implant material is crucial for the success of adjuvant radiation therapy. This makes icotec implants the ideal choice for the treatment of spinal tumors and metastases.","og_url":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/","og_site_name":"icotec","article_modified_time":"2023-03-28T10:16:44+00:00","og_image":[{"url":"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/","url":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/","name":"Optimal Radiation Therapy for Spinal Tumor Patients I icotec","isPartOf":{"@id":"https:\/\/www.icotec-medical.com\/en-us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#primaryimage"},"image":{"@id":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#primaryimage"},"thumbnailUrl":"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png","datePublished":"2021-12-19T17:56:14+00:00","dateModified":"2023-03-28T10:16:44+00:00","description":"The right implant material is crucial for the success of adjuvant radiation therapy. This makes icotec implants the ideal choice for the treatment of spinal tumors and metastases.","breadcrumb":{"@id":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#primaryimage","url":"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png","contentUrl":"https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2022\/12\/08_ErweiterteTherapie_w-bg@4x.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/radiation-therapy\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.icotec-medical.com\/en-us\/"},{"@type":"ListItem","position":2,"name":"Tumor Therapy","item":"https:\/\/www.icotec-medical.com\/en-us\/tumor-therapy\/"},{"@type":"ListItem","position":3,"name":"Radiation Therapy"}]},{"@type":"WebSite","@id":"https:\/\/www.icotec-medical.com\/en-us\/#website","url":"https:\/\/www.icotec-medical.com\/en-us\/","name":"icotec","description":"Innovative Implantate aus kohlefaserverst\u00e4rktem Kunststoff","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.icotec-medical.com\/en-us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/pages\/4273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/comments?post=4273"}],"version-history":[{"count":0,"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/pages\/4273\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/pages\/4330"}],"wp:attachment":[{"href":"https:\/\/www.icotec-medical.com\/en-us\/wp-json\/wp\/v2\/media?parent=4273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}